Refrigeration and Air Conditioning Technology (8th Edition)
Verified Answer ✓
...... more
Verified Answer ✓
The function of a multipoise or multipositional ... more
Verified Answer ✓
Draft safeguard switch is also known as vent limit... more
Verified Answer ✓
For example, in furnaces, they monitor the hot ... more
Verified Answer ✓
The specific gravity of natural gas ranges between... more
Verified Answer ✓
A digital manometer is used to determine the gas ... more
Verified Answer ✓
Verified Answer ✓
Look air is mixture of several gases out of which ... more
Verified Answer ✓
This is a simple question regarding the furnace, ... more
Verified Answer ✓
Air and gas never mix completely in the mixing ... more
Verified Answer ✓
B. Decrease the pressure to the burner more
Verified Answer ✓
False. Not all gas valves snap action open or ... more
Verified Answer ✓
D. All of the above more
Verified Answer ✓
......... more
Verified Answer ✓
..... more
Verified Answer ✓
The pilot is lit every time there is a call for ... more
Verified Answer ✓
In a direct burner gas valve arrangement the ... more
Verified Answer ✓
Inshot burners are usually used with induced draft... more
Verified Answer ✓
Verified Answer ✓
.... more
Verified Answer ✓
The amount of delay before shutting the fan off to... more
Verified Answer ✓
DIP switches are switches that are used to manage ... more
Verified Answer ✓
Verified Answer ✓
Aerated Pilot Light:The aerated pilot is blended ... more
Verified Answer ✓
A thermocouple is a passive device and produces ... more
Verified Answer ✓
The thermocouple on gas combustible heating ... more
Verified Answer ✓
Flame-proving system is used as safety device when... more
Verified Answer ✓
With liquid filled flame-proving systems, you have... more
Verified Answer ✓
..... more
Verified Answer ✓
In the flame rectification method, an exceptional ... more
Verified Answer ✓
Hot surface ignition system removes the pilot ... more
Verified Answer ✓
Flame rectification system can be classified as ... more
Verified Answer ✓
MicroampsThe flow of current is very less hence ... more
Verified Answer ✓
Direct-vent (two-pipe) system: The two-pipe system... more
Verified Answer ✓
A non-direct vented furnace uses inside the room ... more
Verified Answer ✓
A furnace that has a positive pressure venting ... more
Verified Answer ✓
The temperature at which condensation process ... more
Verified Answer ✓
The terms excess air are commonly used to define ... more
Verified Answer ✓
It is used in furnaces to reduce the pollution and... more
Verified Answer ✓
Following factors are mainly used to determine the... more
Verified Answer ✓
....... more
Verified Answer ✓
I have explained the answer itself, so it is easy ... more
Verified Answer ✓
Pre-purge is part of a automotatic control system ... more
Verified Answer ✓
Say for example when firing a boiler, interpurge ... more
Verified Answer ✓
Smart valves are generally more expensive hence ... more
Verified Answer ✓
Pipe in the farnace called as manifold. Gas flows ... more
Verified Answer ✓
Manifolds are fixtures that supply gas to various ... more
Verified Answer ✓
Orifice is a device which is a measuring as well ... more
Verified Answer ✓
Verified Answer ✓
Heat exchanger is a device that is used to ... more
Verified Answer ✓
Types of fan switches are: 1. Time delay fan ... more
Verified Answer ✓
Closing of gas valves.The limit switch consists of... more
Verified Answer ✓
.... more
Verified Answer ✓
Working of two stage furnace A two-stage furnace ... more
Verified Answer ✓
When it is on in, it functions just like single-... more
Verified Answer ✓
Verified Answer ✓
Metal vents are mostly used than a masonry ... more
Verified Answer ✓
These are dampers that automatically shuts off ... more
Verified Answer ✓
gas is flammable so flame used to check totally ... more
Verified Answer ✓
....... more
Verified Answer ✓
To check the efficiency of a fire tube or water ... more